Fill the 1-liter bottle with distilled water and attach it to the humidifier base. Place the probe inside the incubator at egg height, away from the fan. Run the tubing through a ½-inch vent hole, plug the unit in, and set your target humidity on the digital hygrostat. Wait 24 hours for the reading to stabilize before you trust it. Setup takes about 10 to 15 minutes.
Humidity swings ruin more hatches than a bad thermostat ever will. You can hold temperature within half a degree for the entire incubation period and still end up with a chick stuck to the shell membrane, or a soggy hatch tray, because the humidity drifted while you were at work, asleep, or not thinking about a water trough.
If you are tired of babysitting that trough, the HumidiKit automatic humidity system is the fix, and installing it takes about ten minutes once you know where the small snags are.
We support this product every day at Incubator Warehouse, so this guide covers what actually comes up: probe placement, refill timing, the right humidity for each egg type, and fixes for the handful of problems that trip people up.
Although we focus on the HovaBator 1588 Genesis, 1602N, and 2370, the same steps apply to most incubators with a ½-inch vent hole.
Why Humidity Control Matters for Hatching Eggs
Humidity controls how fast an egg loses moisture, and that decides whether the chick can hatch. Every fertile egg loses moisture through its shell during incubation. That is normal and necessary, because the chick needs an air cell of a specific size to orient itself and hatch. If the incubator runs too dry, the chick can shrink-wrap and stick to the membrane at hatch. If it runs too wet, the air cell stays too small, and the chick can drown before it pips.
For most chicken eggs, the target is roughly 45 to 50 percent humidity for days 1 through 18, then 65 to 70 percent for the final three days of lockdown. Knowing the number is the easy part. Holding it for three weeks is where a plain water trough falls apart, since it depends on surface area, room temperature, and how often you remember to top it off. A hygrometer-controlled system like the HumidiKit removes that drift. For more on the fundamentals, read our guide to incubator humidity control and hatch rates.
What the HumidiKit Is and How It Works

The HumidiKit is a two-part system: a small ultrasonic humidifier and a digital hygrostat with a remote probe. The probe sits inside the incubator and measures the real humidity there, not the humidity in the room. The hygrostat compares that reading with your target and switches the humidifier on and off automatically.
It works like a thermostat for moisture. You set a target, such as 50 percent. The humidifier runs until the incubator reaches 50 percent, then shuts off, and it starts again once humidity drops about two points below the target. Two limits are worth knowing:
- It adds humidity but does not remove it: If your room air is very humid, you will need to open vents to bring the level down.
- It stops when the bottle is empty: If the water runs low, the unit simply stops running.
| HumidiKit at a Glance | Detail |
|---|---|
| Type | Automatic ultrasonic humidifier with programmable digital hygrostat |
| Water capacity | 1 liter, distilled water recommended |
| Refill interval | About once a week in a tabletop incubator |
| Connection | Tubing (extends up to 30 inches) through any ½-inch vent hole |
| Power | 110/120V AC, roughly 30 watts |
| Customer rating | 4.1 out of 5 across 41 reviews on the product page (as of November 2026) |
| Warranty | 2-Year IncuCare Warranty |
What You Need Before You Start
- HumidiKit unit, including the humidifier base, hygrostat, probe, tubing, 1-liter bottle, and bottle adapter
- Distilled water, since tap water shortens the life of the ultrasonic disc and leaves mineral buildup on the sensor
- A flat, stable surface next to your incubator, level with or slightly below it
- One open ½-inch vent hole on your incubator
- Optional: a separate thermometer and hygrometer, such as the IncuTherm Plus Hatch Monitor, to cross-check the reading
Add automatic, hands-off humidity control to your incubator in one order.
Shop the HumidiKitStep by Step: Installing the HumidiKit

- Check the parts. Lay out the humidifier base, hygrostat with probe, tubing, bottle, and bottle adapter. Confirm nothing was damaged in shipping before you thread anything into the incubator.
- Fill the bottle with distilled water and screw on the bottle adapter snugly. Do not overtighten it. A lid that is too tight can make the bottle collapse as water is drawn out, while one that is too loose lets water flood the reservoir all at once.
- Attach the bottle to the humidifier base. Keep it upright and stable. A tilted bottle is one of the most common causes of leaks. Use the supplied bottle: we do not recommend a bottle larger than one liter, as it can harm the ultrasonic disc and tip over.
- Choose a vent hole and run the tubing through it. Choose a ½-inch vent close to the humidifier that doesn't block the egg turner or the viewing window. Leave some slack so the tube does not kink, and let the end rest a few inches above the egg trays instead of pointing at the eggs.
- Position the probe inside the incubator at roughly egg height, away from the fan's direct airflow and away from the tubing outlet. This is the step behind most installation complaints. See the placement table below.
- Set the hygrostat where you can see it, on top of the incubator or on a nearby shelf. You will adjust it during the first hatches, so keep it within reach.
- Plug the HumidiKit into power. The switch on the back typically shows a dash as "on" and a circle as "off," but a few units have shipped with the switch attached backward. It does not affect how the unit works, but if you are unsure, flip the switch, watch for the mist to start, and mark the housing.
- Set your target humidity (see the table in the next section) and close up the incubator.
- Wait 24 hours before trusting the reading. Humidity takes longer than temperature to settle, and opening the incubator repeatedly resets the clock.
Probe placement by HovaBator model
| Model | Vent location | Best probe placement |
|---|---|---|
| HovaBator Genesis 1588 | Rear or side vents | Side wall at egg height, clear of the digital control center's airflow |
| HovaBator 1602N | Top and side vents | Side wall, away from the humidifier's tubing outlet since this is a still air model |
| HovaBator 2370 | Side vents near the fan | Opposite side of the cabinet from the fan, so forced air does not skew the reading |
Choosing between these incubators first? See our HovaBator 2370 vs Genesis 1588 comparison, or follow our HovaBator 2370 setup guide.
Setting the Right Humidity for Your Eggs

For chicken eggs, set the HumidiKit to 45 to 50 percent for days 1 to 18, then raise it to 65 to 70 percent for the final three days. Raise the setpoint two to three days before hatch to soften the membrane for pipping.
| Egg type | Setting period humidity | Lockdown humidity (last 3 days) |
|---|---|---|
| Chicken | 45 to 50 percent | 65 to 70 percent |
| Duck | 55 to 65 percent | 75 to 80 percent |
| Quail | 40 to 45 percent | 65 percent |
| Goose | 55 to 65 percent | 75 to 80 percent |
Treat these as starting points rather than fixed rules, since your ideal baseline depends on your local climate. Hatchers in dry regions usually run the higher end of each range. Hatchers in humid climates often run the lower end and may need to crack a vent during lockdown. For full species charts, see our egg incubator temperature and humidity chart.
Troubleshooting Common Problems

| Problem | Likely cause | What to do |
|---|---|---|
| Water collecting in the tubing or dripping into the incubator | Humidifier base sitting higher than the incubator, or on an uneven surface | Move the unit level with or slightly below the incubator and keep the tubing as straight as possible without excess sag |
| Humidity reading will not stabilize | Not enough time has passed, or the probe sits in the fan's airflow | Wait the full 24 hours, then move the probe away from direct airflow if it continues |
| Humidity rises after the humidifier turns off, or drops after it turns on | Normal operation: vapor needs time to disperse from the tube | Check for puddling water in the incubator. Otherwise, no action is needed |
| Humidity will not rise | Empty bottle, kinked tubing, too much air escaping through open vents, or a cold draft on the probe | Check the water and tubing, partially close unused vents, and shield the probe from drafts. In very dry climates, one HumidiKit may not be enough for a large cabinet |
| Humidifier keeps running past the set point | Hygrostat switch sticking on | Contact Incubator Warehouse. We have replaced the older mechanical switch with a more reliable solid-state switch |
| Screen shows LLL or HHH | Sensor disconnected or defective | Check the sensor connections at both ends, and contact us to replace the sensor if the message stays |
| Bottle collapsing or overflowing | Adapter lid tightened too much or too little | Aim for a snug, not maximum tight, seal |
| Inconsistent readings after weeks of use | Buildup inside the grey sensor cage on the probe | Pop the cage open and clear dust or residue from the vents |
| Not sure if the unit is on | Power switch occasionally ships wired backward | Flip the switch, watch for the mist, then mark the housing |
Still stuck? Our guide to lowering humidity in an incubator covers the opposite problem, and our incubator humidity sensor guide explains when to replace a sensor.
Calibration, Cleaning, and Maintenance
Check the HumidiKit's reading against a second hygrometer: Digital hygrostats can drift a few points, so place a separate thermometer and hygrometer a few inches from the probe, not touching it and not in the mist path. A difference of up to 3 to 5 percent between the two is normal for consumer-grade sensors. Let both run for 24 to 48 hours before changing anything. If the second reading is consistently higher or lower, adjust the HumidiKit's setpoint by the difference rather than chasing the display number.
- Use distilled water to prevent mineral buildup that can clog the humidifier and shorten its life.
- Refill about once a week: A tabletop incubator typically draws through a full liter in five to seven days. Expect faster use in dry climates, large cabinets, or if you open the incubator often.
- Check the sensor cage at every refill: A clean sensor is the easiest way to avoid slow drift.
- Clean between hatches: Empty and rinse the bottle, wipe the accessible parts of the tubing, and run a short cycle with distilled water only before storing the unit.
If a part wears out, we stock a replacement HumidiKit sensor, a cooling fan, and a replacement tube with adapter. Browse them all in the HumidiKit replacement parts collection.
Compatibility: What It Works With and What It Does Not
The HumidiKit works with most tabletop and cabinet incubators that have a ½-inch vent hole and room for the probe. That includes the HovaBator Genesis 1588, 1602N, and 2370, as well as the AccuHatch and IncuView models. We have also tested it in cabinet incubators about the size of a GQF cabinet, where it works well. A much larger cabinet may need a larger hose to deliver enough mist.
- Nurture Right 360 and Maticoopx: a dedicated hose adapter makes the fit work.
- Brinsea models: not compatible, because they have no opening for the hose or the probe.
You do not have to run the HumidiKit for the whole incubation period. Some hatchers install it from day one for consistent humidity, while others add it only for lockdown, the three-day window where humidity swings matter most and the incubator is opened least. Both approaches work.
Is the HumidiKit Worth It?
It is most worthwhile if you hatch in a dry climate, hatch humidity-sensitive eggs such as waterfowl, or are tired of refilling water channels by hand. Owners in dry regions often report the biggest improvement, since ambient air alone cannot keep many incubators in range. If you only hatch a few times a year in a humid climate, manual water channels may be enough.
Customer experience is mixed. About two-thirds of reviews on the product page are five stars, and most praise how steady the humidity stays. A minority report leaks or a unit that stopped working. Keep it level, use the supplied 1-liter bottle with distilled water, and contact our team if anything misbehaves, since every unit is covered by the 2-Year IncuCare Warranty.
Add an independent thermometer and hygrometer for a second reading, or stock up on humidity accessories before your next hatch.
Shop IncuTherm Plus Shop Humidity AccessoriesFAQs About the HumidiKit
How do you install the HumidiKit on a HovaBator?
Fill the 1-liter bottle with distilled water, attach it to the humidifier base, place the probe inside the incubator at egg height away from the fan, run the tubing through a ½-inch vent hole, plug the unit in, and set your target humidity on the hygrostat. Wait 24 hours before trusting the reading.
How often does the HumidiKit water reservoir need refilling?
About once a week in most tabletop incubators. The bottle holds 1 liter, and the unit only runs the humidifier when humidity needs a boost. Dry climates, large cabinets, and frequent opening of the incubator mean more frequent refills.
What humidity should I set on the HumidiKit for chicken eggs?
Set it to 45 to 50 percent for days 1 to 18, then raise it to 65 to 70 percent for the final three days of lockdown. Adjust within these ranges for your climate.
How does the HumidiKit control humidity?
A probe inside the incubator measures humidity, and a digital hygrostat compares it with your target. The humidifier runs until the target is reached, then turns off, and starts again when humidity drops about two points below the target.
Does the HumidiKit lower humidity if it gets too high?
No. It only adds humidity. To lower humidity, open the vent caps and wait about an hour, and remove some water from the incubator's water channels if needed.
Does the HumidiKit work with the HovaBator 1588 Genesis, 1602N, and 2370?
Yes. It connects through any ½-inch vent hole, so installation is similar across these models, and it also works with most incubators that have a vent hole and room for the probe.
Which incubators is the HumidiKit not compatible with?
It does not work with Brinsea models because they have no opening to accept the hose or the probe. The Nurture Right 360 and Maticoopx need a dedicated hose adapter.
Do I have to use distilled water in the HumidiKit?
Distilled water is recommended. Tap water works in a pinch, but mineral deposits build up faster, can clog the humidifier, and leave residue on the sensor.
Can I use a bigger water bottle with the HumidiKit?
We do not recommend a bottle larger than one liter. An oversized bottle can damage the ultrasonic disc and may not support itself, which can cause spills that damage the unit.
What happens if the HumidiKit runs out of water?
The unit simply stops running until you refill the bottle, so check it at least once a week.
Why does my HumidiKit show LLL or HHH?
This usually means the sensor is disconnected or defective. Check the sensor connections at both ends, and contact Incubator Warehouse for a replacement if the message continues.
Why does my HumidiKit read differently from my other hygrometer?
Probe placement is the most common cause. If the probe sits in direct fan airflow or too close to the mist outlet, the reading will skew. A difference of up to 3 to 5 percent between two consumer-grade sensors is normal, so adjust the setpoint by the difference rather than chasing the display number.
Can the HumidiKit be used for reptile eggs?
Yes, as long as the incubator has a ½-inch vent hole for the tubing and enough interior space for the probe. See our guide on hatching reptiles in a poultry incubator.
Is the HumidiKit covered by a warranty?
Yes. The HumidiKit is backed by the 2-Year IncuCare Warranty when purchased from Incubator Warehouse.
Stop refilling water troughs by hand and let the HumidiKit hold your target humidity from day one through hatch day.
Shop the HumidiKit Shop HovaBator 1588 Kits Shop HovaBator 2370 Kits